Chongqing Sunflower Instrument Co,.Limited

WNG-11/WNY-11 Metal sleeve glass alcohol kerosene mercury thermometer marine thermometer

WNG-11/WNY-11 Metal sleeve glass alcohol kerosene mercury thermometer

 

The metal sleeve thermometer can be used for boiler measurement. It is an on-site detection instrument for measuring medium and low temperatures. It can be used to directly measure or control the temperature of gases and liquids. It has the characteristics of high measurement accuracy and sensitive response. Xinwang Instrument produces glass thermometers for various purposes, with complete specifications and varieties, stable and reliable quality, and can be specially manufactured for users. Products are widely used in various industries in industry, agriculture, scientific research and other fields. WNG type is mercury, WNY type is organic liquid.

 

The WNY-11 metal sleeve glass kerosene thermometer is made using the principle of thermal expansion and cold-heat shrinkage of a temperature-sensitive liquid (mercury or organic liquid). When the temperature of the measured medium changes, the liquid column of the temperature-sensing body in the thermometer changes up and down. The height indicated by the liquid can indicate the temperature of the measured medium.

 

WNG/WNY series glass thermometers are divided into: internal standard type, rod type; can be made straight, 90° angle, 135° angle; measuring range: -80℃~+500℃; indication error value: generally 1 point 1.5 to 2 times the grid value; engineering pressure: 6.4MPa for thermometer with metal protective sleeve

 

There are two types of WNG/WNY glass rod thermometers. One is a rod type (without protective cover) glass thermometer: WNG/WNY-01 (straight), WNG/WNY-02 (90° angle), WNG/WNY- 03 (135°angle shape); the other is a glass thermometer with a metal protective cover: WNG/WNY-12 (90°angle shape), WNG/WNY-13 (135°angle shape)

The main technical parameters of the metal sleeve thermometer

(1) Type: internal standard type, rod type: straight, 90° angle, 135° angle

(2) Measuring range: -80~+500℃

(3) Indication error limit: generally 1.5-2 times of 1 division value

(4) Nominal pressure: 6.4MPa for thermometer with metal protective sleeve

1. WNG (Y) type internal standard glass thermometer

 

Model specifications and dimensions are shown in Table

Model

 

range℃ accuracy℃ Upper body mm Immersion mm
Length L Shell D Length 1 dia
straight angle
WNY-11(straight)
  WNY-12(90°angle)
  WNY-13(135°angle)
-80~+30* 1 220(or 150) 18±1 600-5
  800-5
  1000-5
  1200-10
  1600-10
  2000-10
  2500-10
  3200-10
  4000-10
  5000-10

 

1100-10
  1300-10
  1500-10
  1700-10
  2100-10
  2500-10
  3000-10
  3700-10
  4500-10
  5500-10
8±1
-50~+30*
-30~+70
0~50 0.5
0~70 1
0~100
0~150
WNG-11(straight)

WNG-12(90°angle)

WNG-13(135°angle)

0~150 1 220(or 150) 18±1 60-500
 
  6300-10
  1000-10
  8000-10
  10000-10
  12500-10
  16000-10
  20000-10
110-550
 
  6800-10
  8500-10
  10500-10
  13000-10
8±1
0~200 1 or 2 9±1
0~300 2
0~400 2 or 5
0~500     5

Note:

(1) For the measuring range with “*”, the length of the lower body is 1≥100mm

(2) WNG type temperature sensing liquid is mercury, WNY type is organic liquid.

If the measuring range is ≤100℃ due to the special needs of users,

mercury is still needed as the temperature sensing liquid, please specify in the contract.

2. WNG (Y) type internal standard glass thermometer with metal protective sleeve

The external installation dimensions of the metal protective sleeve are shown in Table 2

Upper body Immersion 安装螺纹A Shell material
Outer dia D Length 1 Diameter d
straight angle
244 263 25 See above table 12
  14
  16
M27×2
  G3/4
  G1/2
  G3/8
钢10黄铜HPb59-1或H62不锈钢1Cr18Ni9Ti
Model Range℃ Accuracy℃ Total Immersion Upper length Lower body Probe dia  dia
  mm
WNY-01(straight type) -80~+70 1 300
  350
75 230
  280
  300
  400
 

1100-10
  1300-10
  1500-10
  1700-10
  2100-10
  2500-10
  3000-10
  3700-10
  4500-10
  5500-10

7±1
WNY-02(90°angle type) 0~5 0.5或1
WNY-03(135°angle type) 0~100 1
0~150
WNG-01(straight type ) 0~150 1 400

500

100
WNG-02(90°angle type) 0~200 2
0~300
WNG-03(135°angle type) 0~400 5
0~500 5
PREV
NEXT

RELATED POSTS